Prochem V

Quick and easy veterinary and research chemistry

Prochem V
Features Operation Screens Reports Brochure

Features :

  • 25 biochemistry parameters available to run, including T4 and electrolytes
  • Users can run any combination of chemistries from 1 single test to a full 25 chemistry profile
  • Multiple patients can be run at the same time
  • No calibration necessary
  • Individually sealed QVETs for optimum usage

Background :

The Prochem V system takes a unique approach to the challenges of veterinary and research biochemistry. Each chemistry is self contained in a QVET. The user can define which chemistries they want to run (so are not reliant on somebody else choosing the profile). The samples are loaded into the QVETs which are then loaded into the system and the run commenced.
Because the unit can also perform electrolyte analysis, there is no need to purchase a separate electrolyte unit. The Prochem V is so flexible it can even do T4.


Chemistries :

Albumin, ALKP, ALT(SGPT), Amylase, AST(SGOT), Bicarbonate, Bilirubin(T), BUN, Calcium, Chloride, Cholesterol, Creatinine, CK, GGT, Glucose, Iron, LDH, Lipase, Magnesium, Phosphate, Potassium, T4, Total Protein, Triglycerides, Uric Acid.

Technology :

Each chemistry uses wet reagents. The method chemistries are selected to provide optimum performance. As the Prochem V uses wet chemistry, the results do not suffer from matrix effects like some other methods, such as dry chemistry do. The Prochem V has none of the drawbacks of traditional wet chemistry systems as all the reagents are contained in individual QVETs.
Each QVET is barcoded for ease of use. Once analysis is started the Prochem V mixes, reads and prints the results automatically.


Operation :

Sample type/handling :
Serum is the preferred sample type. Some chemistries can use plasma

Sample Volume :
Sample volumes vary from 5 to 50 µL, depending on the chemistries run.

Sample cycle :
Depends on the number and type of chemistries run.

Data Input :
Through keyboard

Data Output :
Results are printed out using a standard inkjet printer. Results are also displayed on the display screen and stored electronically on the Prochem V. Data can be transmitted via an RS232 port.

Flagging :
A full range of species specific ranges are held in the Prochem V, thus enabling you to detect abnormal results. A full range of error codes is also provided to aid in dealing with peculiar samples and troubleshooting.

Species :
The Prochem V can run samples from any species. Ranges for dogs, cats, horses, cows and pigs are stored in the system. For any other species, results will be printed out without reference range data.

Calibration :
The Prochem V chemistries are calibrated in our manufacturing facility. Each batch is assigned a special factor which the user enters into the Prochem V with every new batch.

Quality Control :
The Prochem V Multiqual is a liquid based quality control that has assigned values for the Prochem V chemistries. The Multiqual can be used to check the performance of chemistries on the Prochem V.


Dimensions :

Dimensions
Weight
Operating conditions : Temperature :
Humidity :
Power:


Ordering Information :

Part code Description
INSTRUMENTATION
2001 Prochem V with keyboard
PROCHEM V CONSUMABLES
( The unit is one tray of 10 tests, except T4 which is a tray of 9 tests. )
3001VT Albumin
3002VT Alkaline Phosphate
3103VT ALT/SGPT
3104VT Amylase
3108VT AST/SGOT
3005VT Bicarbonate 
3007VT Bilirubin-Total 
3008VT BUN
3009VT Calcium
3010VT Chloride
3011VT Cholesterol
3110VT CK
3012VT Creatinine
3118VT GGT
3013VT Glucose
3014VT Iron
3135VT LDH
3138VT Lipase
3016VT Magnesium
3017VT Phosphate
3018VT Potassium
3210VT T4 (9 test tray)
3020VT Total protein
3021VT Triglycerides
3022 Uric Acid
QUALITY CONTROL
4004VV Multiqual 2 ( 1 x 3ml vial)

Example Screen :

Prochem V menu screen

Example Report :

Brochure :

You need Adobe Reader to view or print the brochure. If you do not already have the Reader, then you can download it, free of charge, from Adobe. More details ...

Click here to view or print the Prochem V brochure