Intended Use :
Fast, Convenient Veterinary cell counter, for Research applications.
Features :
- 20 parameters, including platelets
- Fast - 26 samples per hour
- Complete 5 part WBC differential
- Designed specifically for veterinary medicine
- Patented Expectation Maximisation software
- Fully automated, whole blood open vials
- Simple to operate
- Low maintenance, due to Focused Flow® technology
- Optimized Reagents and Controls
- Efficient, cost effective patient management
Parameters :
WBC, NE#, NE%, LY#, LY%, MO#, MO%, EO#, EO%, BA#, BA%
RBC, Hb, HCT, MCV, MCH, MCHC, RDW
plus additional flagging for NRBC#, NRBC%, see note
Platelet Count, MPV
3D cytograms : WBC subpopulations, RBCs, PLTs
Note : Differential parameters and abnormal flagging
not available with all Species
Species
Up to Six Dedicated Pre-programmed Species Keys.
(Additional species can be run on 'OTHER' key)note1 |
| Available Species : |
| |
Bison, Calfnote2, Camel², Cat, Cow, Deer²,
Dog, Elephant², Elk4, Ferret², Foal², Goat²,
Guinea Pig², Horse, Llama², Monkey, Mouse, Pig4,
Pre-Dilute Mouse, Pre-Dilute Rat, Rabbit4, Rat, Sheep4 |
| Note 1 : |
Differential parameters and flagging not available with
"OTHER" key |
| Note 2 : |
Differential parameters and abnormal flagging not available
with all Species |
| Note 3 : |
Extended MCV linearity range (10 to 600 fL) available
for Exotic Species Packages, eg Goat, Llama |
| Note 4 : |
RBC and PLT Cytograms not available with all Species |
Operation :
| Sample Delivery : |
Automated open vial sample delivery. Automated probe
wiping. One touch walk-away sample processing. |
| Sample Volume : |
20 µL whole blood Sample. |
| Throughput : |
Approximately 26 samples per hour. |
| Data Input / Output : |
Touch Keypad with Six Dedicated Species Keys and one 'OTHER' key
LCD display.
Customised report (8.5" x 11") with exclusive 3-D cytograms
of WBC and RBC subpopulations.
RS232 port for external computer interface.
|
| Patient Storage : |
Internal data Storage for last 50 samples run. |
| Flagging : |
Automatic distribution and morphological flagging.
Hematologic abnormality charts indicating Mild, Moderate and Severe conditions. |
Performance :
| Precision : |
| WBC |
10.0 |
x
10³ cells/µL |
< 3.0% |
| RBC |
7.0 |
x 106 cells/µL |
< 3.0% |
| Hb |
14 |
g/dL |
< 2.0 % |
| MCV |
60 |
fL |
< 1.0 % |
| PLT |
500 |
x 10³ cells/µL |
< 5.0 % |
| NE# |
6.0 |
x 10³ cells/µL |
< 6.0 % |
| LY# |
6.0 |
x 10³ cells/µL |
< 6.0 % |
| EO# |
2.0 |
x 10³ cells/µL |
< 12.0 % |
| Linearity : |
| WBC |
0.1 to 200.0 |
x 10³ cells/µL |
|
| RBC |
0.01 to 20.0 |
x
106 cells/µL |
|
| Hb |
0.1 to 35 |
g/dL |
|
| MCV |
30 to 300 |
fL note3 |
|
| PLT |
1 to 4000 |
x 10³ cells/µL |
|
| NE% |
0.1 to 99.9% |
|
|
| LY% |
0.1 to 99.9% |
|
|
| EO% |
0.1 to 99.9% |
|
|
Note 3 : Extended MCV linearity range (10 to 600 fL) available
for Exotic Species Packages, eg Goat, Llama.
Dimensions :
| Dimensions : |
Height : 12" (30.5 cm)
Width : 10.5" (27 cm)
Depth : 20" (51cm) |
| Weight : |
25.5 lbs (11.6 Kg) |
| Operating Temperature : |
62ºF to 90ºF (17ºC to 32ºC) |
| Voltage : |
95 to 132 VAC or 180 to 264 VAC 47 to 63 Hz |
Consumables :
| Reagent
Kit : |
| |
Reagent
Kit optimized for the Hemavet 950. This kit yields approximately 135
billable tests per reagent kit when running 15 samples per day. |
| Controls
: |
| |
Dog,
Cat, Mouse and Horse Controls are available. |
| Calibration
: |
| |
Drew Scientific recommends running a
control each day. The calibration should be reviewed every six months.
Adjust as necessary. Review after replacing worn or damaged components.
|
| FS-PAK |
200106 |
| MULTI-TROL Dog |
600066 |
| MULTI-TROL Cat |
600064 |
| MULTI-TROL Mouse |
600065 |
| MULTI-CAL Kit |
610020 |
Screen and Keypad:
|
|
Typical Species Keys :
|
|
Example Report :
Brochure :
You need Adobe Reader to view or print the brochure.
If you do not already have the Reader, then you can download it, free
of charge, from Adobe. More details
...
Click here to view or
print the Hemavet brochure
|
 |